RAPID INTERVENTION CAPNOGRAPH
RICap CO2 Monitor is intended to provide continuous monitoring of end tidal CO2 concentration (EtCO2), Capnogram, Respiration Rate (RR) of adult, paediatric and infant patients. As a life saving device during Rapid Intervention, RICap fnds its place in emergency departments just as much as in perioperative departments, spot check for both intubated and non-intubated patients, and during transport not only in ambulances but even within the hospital. Splashproof, lightweight and ftting in the palm of a hand, starting up within seconds, it is an excellent device that can be used directly by both ALS and BLS providers. RICap waveform allows a quick evaluation of the patient respiratory distress help healthcare personel for a rapide intervention.
Features
High standard Accuracy CO2 measurement by dual wave length
Splash proof and rugged design for use in harsh conditions
4 buttons for convenient settings adjustments, alarm pause and power on/of
Adjustable Sweep speed
Selectable units mmHg, kPa, %
Apnea detection and adjustable
Confgurable alarms for Respiration rate alarm, EtCO2 high and low, clogged or missing adapter
Low battery indicator
Visual and audible (buzzer) alarm
Real-time Capnogram display
Up to 3.5 hours continuous use
Adult and neonatal airway adapters
Ultra lightweight
No annual routine calibration required
Support english, italian, french, hungarian, polish (other language upon request)
Bluetooth connectivity to export real time data
SPECIFICATIONS
Mechanical and Environment
Dimensions: 60 x 47 x 43 mm (2.36 x 1.85 x 1.69 inches)
Weight: ~80 g (complete device with batteries), < 350grs with transport pouch.
Mechanical robustness: Meets the shock and vibration requirements for transport of SS-EN
ISO 21647:2004 clause 21.102Temperature and Humidity Operating: -5 to 50ºC, 10 to 90% RH, non-condensing
Storage: -30 to 70ºC, <90% RH, non-condensingAtmospheric pressure 70 – 120 kPa
EtCO2 Measurement
Transducer: Type Mainstream CO2 Monitor
Measuring method: Dual-wavelength, non-dispersive infrared spectroscopy
Initialization Time: Capnogram, displayed within few seconds at an ambient temperature of 25ºC, and full specifcations within 1-2 minutes especially if temperature below 15ºC
CO2 Measurement: Range 0 to 99 mmHg, 0 to 9.9%, 0 to 9.9 kPa
CO2 Accuracy: ±(0.2% + 2% of reading)
Total system response time: < 1s
Calibration: No routine user calibration required. An airway adapter zero is required when
changing to a new airway adapterRecovery time afterdefbrillator test: Unafected
Respiration Rate Measurement
Respiratory rate Range: 2~150 Breaths Per Minute (BPM)
Respiration Rate Accuracy: ±1BPM
Breath detect: Adaptive threshold, minimum 1 % CO2 change
Airway Adapters: < 5 cc dead space (adult/Pediatric), < 1 cc dead space( infant)
Human Machine Interface
Display: Active OLED color graphic display, 65 000 colors, 128 x 128 pixels
Multi-languages(English, French, Italian, Hungarian, polish and more to be supported)Front Panel Buttons: 4 buttons: power on/of, alarm pause, up/down selection
Alarms: No Adapter, Clogged Adapter, No Breath Detected, High AwRR, Low ETCO2,
High ETCO2, Temperature out of range, Atmospheric pressure is over
operating range, Low Battery
Power Specifcations
External Supply: None
Power Consumption: TBD
Batteries: Two AAA Cell batteries (2×1.5VDC): Alkaline IEC:LR03 or Energizer Ultimate Lithium L92 batteries. Use of other Lithium batteries may present a risk of fre or explosion
Battery life time
Duracell Plus Alkaline: ~4 hours
Energizer Ultimate Lithium L92: ~7 hours
Regulatory Compliance
Certifcate: CE
Standards compliance:
MDD 93/42/EEC
EN 60601:1990, Amendment 1 (1991), Amendment 2 (1995)
EN 60601-1-2:2001
EN 60601-1-8:2004
EN ISO 21647:2004
EN ISO 5356-1:2004
EN 1789:2007
Box content: RICap capnograph, adult and neonate airway adapters, lanyard and pouch