SpotLife® Vital signs monitor has been designed to serve frontline caregivers in emergency, peri-operative care and ICU/NICU departments. With its accurate oximetry adapted for adults as well as neonates, it provides a continuous and accurate monitoring of the SpO2 and PR even in case of low perfusion. SpotLife® VSM is declined in versions with either NIBP or CO2 measurement with optional fast temperature monitoring. Its handle and lightweight make it easy for transport use while its 4 stable feet allow a reliable use as bedside monitor. Cost effective, it remains a comprehensive device for multiple applications and environments.
All models are based on our SpO2 module and provide the same high performance. The NIBP model will embed in addition our NIBP module, while our CO2 models will be using either our mainstream CO2 or external sidestream CO2 modules.
Features
Bright, large 5” Color TFT LCD for better readability of all parameters.
Intuitive user interface.
4 models availables:
SpO2 only (Model #SPLF-OX)
SpO2 + NIBP (Model #SPLF-NP)
SpO2 + Mainstream CO2 (Model #SPLF-MC)
SpO2 + Sidestream CO2 (Model #SPLF-SE)
Selectable Display Modes:
digits only, showing parameters values
digits and graphs, showing real-time plethysmogram and capnogram/NIBP (according to model)
digits, graph and trends, displaying in addition the historical values.
9 LED indicators to easily control patient type, units, power and alarm status.
New patient presets allowing a one step action to set all alarms limits according to patient type (Adult, Child, Neonate).
360° Visible and Audible alarms.
Over 72h trend data with a 1 min resolution.
Built-in power supply and 2400mAh lithium battery for 6h continuous monitoring.
Extension port upon request for custom protocols, raw data output for research and other device connectivity.
Bluetooth printer connectivity for record printouts.
USB port for easy updates with new software functions (further connectivity and control options, addition of peripherals).
SPECIFICATIONS
Functions
Oximetry (all models)
Real-time measurement of SpO2, pulse rate (PR), perfusion index (PI), and Variability of Pulse Index (PIV).
Real-time photoplethysmogram display
High accuracy and reliability even with low blood perfusion down to 0.05%, allowing application in OR, ICU and NICU.
NIBP (SPLF-NP model)
Measurement of Systolic BP, Mean Arterial Pressure, Diastolic BP using oscillometric method.
3 measurement modes such as manual, auto and continuous.
hardware and software over-pressure protection
Capnography (SPLF-SE and SPLF-MC models)
Measurement of EtCO2, FiCO2 and Respiratory Rate (awRR)
Real-time capnogram display
Automatic barometric pressure, temperature compensation and manual anaesthetic gases compensation
Fixed Micro Flow: 50 ml/min (±10ml/min) (SPLF-SE Model only)
Thermometry (Option TBD):
Body temperature measurement using Fast temperature probe
Environmental characteristics
Operating Conditions
Temperature: 0°C ~ 40°C
Humidity: 15 ~ 95%, non-condensation
Atmospheric pressure: 70.0kPa ~ 106.0kPa
Storage Conditions
Temperature: -20 ~ 70°C (4 to 158°F)
Humidity: 15 ~ 95%, non-condensation
Atmospheric pressure: 57.3kPa ~ 106.0kPa
Electrical and Mechanical characteristics
Electrical Power Supply
AC: 100 ~ 240V ± 10% (built-in adapter)
Input power: 60VA
Frequency: 50Hz/60Hz ± 3Hz
One equipotential grounding interface
Product Class: IIb (in accordance with MDD93 /42/ EEC)
Battery
Built-in rechargeable lithium batteries: 11.1 V / 2400mAh
Mechanical
Dimensions: 255 x 140 x 95mm (LxWxH)
Weight: < 2kg (without accessories)
Interfaces
Connectivity
USB interface
RS232 DB9 interface
HMI
Five buttons: Power switch, alarm stop, alarm pause, up and down buttons, menu
Display: 5” Color TFT LCD, 800 x 480pixels
Audio/Visual Indicators: Alarm limit reached, Alarm tone, Alarm mute, pulse strength, Patient name, Patient Type, Time, battery status, connection status.
LEDs: Adult, Neonate, Pressure Unit or SpO2/PR (according to model), battery in use, battery charging, silenced alarm.
User Interface language: English, French, Italian, Hungarian (additional language upon request).
Performances
SpO2 (all models)
Sp02: Measurement Range: 0 – 100%; Accuracy Range: from 70 – 100 % = ±2%, below 70%, Undefined; Resolution: 1%
Pulse Rate: Measurement Range: 15-300 BPM; Accuracy Range: ±2%; Resolution: 1 bpm
PI: Measurement Range: 0-20%; Resolution: 0.001%
PIV: Measurement Range: 0-100%; Accuracy Range: Undefined; Resolution: 1%
NIBP (SPLF-NP model only)
Method: Automatic oscillometric
Operation modes: Manual, Automatic, Continuous
Automatic mode measurement interval: 1min, 2min, 3min, 4min, 5min, 10min, 15min, 30min, 60min, 90min, 2h, 3h
Continuous mode measurement period: 5mins, with 5s between each measurement
Maximum single measurement time: 180s
Measurement range: –
Systolic BP: Adult mode: 40 ~ 270 mmHg, Pediatric mode: 40 ~ 200 mmHg
Diastolic BP: Adult mode: 10 ~ 210 mmHg, Pediatric mode: 10 ~ 150 mmHg
MAP: Adult mode: 20 ~ 230 mmHg, Pediatric mode: 20 ~ 165 mmHg
Accuracy: Mean error: ±5mmHg, Standard deviation: 8mmHg
Static pressure measurement range: 0 mmHg (0kPa) ~ 300mmHg (39.9kPa)
Static pressure measurement accuracy: ±2mmHg or ±1% of reading (Whichever is greater)
Resolution: 1 mmHg
Initial inflation pressure setting range: Adult mode: 80 ~ 280 mmHg, Pediatric mode: 80 ~ 210 mmHg
Initial inflation pressure default: Adult mode: 160 mmHg, Pediatric mode: 140 mmHg
Software over-pressure protection: Adult mode: 297 ±3mmHg, Pediatric mode: 240 ±3mmHg
Alarm range:
Systolic BP: Adult mode: 40 ~ 270 mmHg, Pediatric mode: 40 ~ 200 mmHg
Diastolic BP: Adult mode: 10 ~ 210 mmHg, Pediatric mode: 10 ~ 150 mmHg
MAP: Adult mode: 20 ~ 230 mmHg, Pediatric mode: 20 ~ 165 mmHg
Capnography (SPLF-MC and SPLF-SE models)
Method: Infrared radiation absorption technology
CO2 measurement range: 0 ~ 20 %
Accuracy:
0 ~ 12% : ±(0.2 Vol% + 2% of reading),
– 12 ~ 20% : ±(0.2 Vol% + 6% of reading)
Measurement accuracy drift: accuracy requirements within 6 hours
Resolution: 0.1 Vol%
Accuracy: Mean error: < ±5mmHg, Standard deviation: < 8mmHg
Apnea alarm delay time: 20s, 25s, 30s, 35s, 40s, 45s, 50s, 55s, 60s
Alarm range:
EtCO2: 0 ~ 150mmHg
FiCO2: 0 ~ 150mmHg
AwRR: 0 ~ 150rpm
Downloads
Click to download
Ordering Information
Model #SPLF-OX : SpotLife® Oximeter Only, with reusable Adult SpO2 probe
Model #SPLF-NP : SpotLife® Oximeter and NIBP, with reusable Adult SpO2 probe and Adult NIBP Cuff
Model #SPLF-MC : SpotLife® Oximeter and Mainstream CO2 sensor, with reusable Adult SpO2 probe, one set of disposable adult and neonate airway adapters
Model #SPLF-SE : SpotLife® Oximeter and External Sidestream CO2 sensor, with reusable Adult SpO2 probe, CO2 microstream sampling line.