Features
Excellent Performance:
> LowPulseStrTM SPO₂ algorithm more reliable readings of SPO₂ during low perfusion and motion.
> iFastBP® NIBP algorithm used for fast and comfortable measurement.
> wSmartHeart® ECG technology for more safey monitoring of patient.
> iRealRespTM Breating rate technology to get the real reading during motion.
> wSmartGas® Capnograph technology to get reliable reading during multi-environment.
Powerful function
> Multi display mode Big font.
> 8 inch screen can be optional.
> Wi-Fi connectivity more flexible application.
> eTeleViewTM Central Montior system support.
> Smart alarm system more safety and more efficient.
> Fanless design.
> Compact design and easy to use.
Multi-scenario Application 
Product Optional Guider
VS 800
|
Standard application
| SpO₂ NIBP | PR TEMP |
Optional application
| Wi-Fi 3 Leads ECG 5 Leads ECG EtCO₂ (Mainstream, TiniStream) | Printer Touch Screen Infrared therometer (Wired) Infrared therometer (Wireless by Bluetooth) |
Central Monitoring System
Central Monitoring System supports up to 64 beds or 64 patients across clinical units at the same time.
240 hours of 64-channel holographic physiological waveform storage and review.
Provides review of up to 240 hours trend data storage, 720 alarm events per beds.
Bi-directional communication with PMVS Series monitors for enhanced patient care.

Product Specifications
GENERAL
Dimensions: 17.5cm*27cm*12.5cm
Weight: 2.4kg(Including battery, built-in module)
Screen size: 8 inches
TEMP
Range: 0-50°C
Accuracy: ±0.1°C
Resolution: 0.1°C
PR
Range: 25~300bpm
Accuracy: ±3bpm
Resolution: 1bpm
SpO₂
SpO2 Range: 0~100%
SpO2Accuracy: 70~100%, ±2% <70%, Undefined
PI Range: 0~20%
PVI Range: 0.001%
NIBP
Static Pressure Range: 0~300mmHg
Static Pressure Accuracy: ±2mmHg or ±1% of reading (take the larger value)
Static Pressure Resolution: 1mmHg
Blood pressure SYS Range: Adult: 40-270mmHg Pediatric: 40-235mmHg Neonate: 25-130mmHg
Blood pressure DIA Range: Adult: 10-210mmHg Pediatric: 10-200mmHg Neonate: 10-90mmHg
Blood pressure Mean Range: Adult: 20-230mmHg Pediatric: 20-225mmHg Neonate: 15-100mmHg
Blood pressure Accuracy: The mean deviation<±5mmHg, The standard deviation<8mmHg
ECG(Optional)
ECG Range: 0.15~5.5mV
ECG Resolution: 2.36uV/LSB
HR Range: 15~300bpm(adult) 15~350bpm(child/neonate)
HR Accuracy: ±1bpm or ±1%(whichone is greater)
RR Range: Adult: 0~120rpm; Pediatric, Neonate: 0~150rpm
RR Accuracy: 15~150rpm: ±2rpm or ±2% <15rpm: Undefined
EtCO₂(Optional)
CO2 Range: 0~20.0vol%
CO2 Accuracy: 0~12vol%: ±(0.2vol%+2%of reading) 12~20vol%: ±(0.2vol%+6%of reading)
AwRR Range: 0~150rpm
AwRR Accuracy: mainstream: 0~150rpm, ±1rpm Sidestream: 0~70rpm, ±1rpm 71~150rpm, Undefined