It is used to monitor the patient's blood oxygen,blood pressure, body temperature, and pulse. 
Description

 Features


With pulse oxygen, pulse rate monitoring function.
With monitoring function of systolic blood pressure, diastolic blood pressure and mean pressure.
With 2 body temperature monitoring functions.
Provide three patient modes: adult, child and newborn mode.
Module thickness is only 25mm, exquisite and compact.
Integrated blood pressure gas circuit system design.
The working status of the real-time transmission module: hardware status, software status and sensor status, the upper computer can alarm in time according to the information.
When the perfusion index is as low as 0.3%, the blood oxygen monitoring is accurate and reliable, meeting the application of surgery and ICU.
Both blood oxygen and blood pressure adopt advanced algorithms, with anti-motion interference and weak signal measurement performance.
Blood pressure measurement has three modes: manual, automatic and continuous mode.
Blood pressure measurement has hardware and software dual overvoltage protection functions.
Double timeout protection for blood pressure measurement (module timeout protection, provide timing trigger port of host computer)


 Specifications


SPO2

Range:0~100%
Accuracy:±2%(70%~100%)Undefined(0~69%)
Resolution:1%

PR

Range:25~300bpm
Accuracy:±3bpm
Resolution:1bpm

PI

Range:0~20%
Accuracy:Undefined
Resolution:0.001%

TEMP

Range: 0-50°C
Accuracy:±0.1°C
Resolution:0.1°C

NIBP

Pressure Range:0-300mmHg
Pressure Accuracy:±2mmHg or ±1% (Whichever is greater)
Resolution:1mmHg
Systolic Range            Adult : 40–270mmHg                           Pediatric : 40–235mmHg                            Neonate : 40–130mmHg           
Distolic Range            Adult : 10–210mmHg                            Pediatric:10–200mmHg                              Neonate:10–90mmHg
Mean Range               Adult : 20–230mmHg                            Pediatric : 20–225mmHg                            Neonate : 20–100mmHg
Accuracy                    The mean deviation<±5mmHg              The standard deviation<8mmHg

Electical Specification

Power supply:DC.12V±5%
Power consumption:≤6W
Communication:TTL,USART
Temperature         Operating 0°C~ 70°C        Storage  -40°C~ 70°C

Compliance

Standard              IEC 80601-2-30: 2018             DIN EN ISO 81060-1: 2012            BS EN 1060-3:1997 +A2: 2009
                           ISO 80601-2-61: 2017


 Downloads


MMPD Multi-parameter_04.pdf


Products:
MMPD
Your email:
Product Tech Research & Articles
No data available
CONTACT
Address:Zug Medical Systems SAS83170 Brignoles France
Phone number:+33 9 84 116 339
facebook
titweer
youtube
link
logo-red
language:
© 2025-2026 Copyright by Zug Medical Systems SAS. All rights reserved.
Technical Support:beautysite.cn